Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Dental press j. orthod. (Impr.) ; 29(1): e2423285, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1534313

ABSTRACT

ABSTRACT Objective: This study aimed to evaluate occlusion development after premature loss or extraction of deciduous anterior teeth, by means of a prospective cohort study. Methods: Fifteen infants and children aged 1 to 5 years old were longitudinally assessed (with loss or extraction of deciduous anterior teeth [n = 9], and without tooth losses [n = 6]). Photographs and dental casts at the baseline and after 24 months of follow-up were performed. Dental casts were scanned, and linear measurements were made on the digitalized models (missing tooth space, arch perimeter, arch length, arch width, intercanine length and intercanine width). The t-test was used for groups comparisons (α = 0.05). Results: Individuals' mean age at baseline was 2.93 (± 1.18) years. No statistically significant differences were observed in the missing tooth space in the group with tooth loss during the 24 months of follow-up (p > 0.05). Arch perimeter, arch length, arch width, intercanine length and intercanine width did not show differences between the groups (p > 0.05). Qualitative photographic evaluation revealed other changes in the dental arches and occlusion, such as exfoliation and eruption of deciduous teeth, eruption of permanent teeth, self-correction or establishment of malocclusion, among others. Conclusion: The results suggest that the premature loss of deciduous anterior teeth does not affect the perimeter, length and width of the dental arches; however, other alterations that lead to malocclusion could be established.


RESUMO Objetivo: Este estudo teve como objetivo avaliar o desenvolvimento da oclusão após perda prematura ou extração de dentes decíduos anteriores, por meio de um estudo de coorte prospectivo. Métodos: Quinze bebês e crianças de 1 a 5 anos foram avaliados longitudinalmente (com perda ou extração de dentes anteriores decíduos [n = 9] e sem perdas dentárias [n = 6]). Foram realizadas fotografias e modelos dentais no início e após 24 meses de acompanhamento. Os modelos dentários foram escaneados e medidas lineares foram feitas nos modelos digitalizados (espaço dentário perdido, perímetro da arcada, comprimento da arcada, largura da arcada, comprimento intercaninos e largura intercaninos). O teste t foi utilizado para comparações entre grupos (α = 0,05). Resultados: A média de idade dos indivíduos no início do estudo foi de 2,93 (± 1,18) anos. Não foram observadas diferenças estatisticamente significativas no espaço dentário perdido no grupo com perda dentária durante os 24 meses de acompanhamento (p > 0,05). O perímetro da arcada, comprimento da arcada, largura da arcada, comprimento intercaninos e largura intercaninos não apresentaram diferenças entre os grupos (p> 0,05). A avaliação fotográfica qualitativa revelou alterações nas arcadas dentárias e na oclusão, como: esfoliação e erupção de dentes decíduos, erupção de dentes permanentes, autocorreção ou estabelecimento de má oclusão, entre outras. Conclusão: Os resultados sugerem que a perda prematura de dentes anteriores decíduos não afeta o perímetro, comprimento e largura das arcadas dentárias; entretanto, outras alterações que levam à má oclusão poderiam ser estabelecidas.

2.
J. health sci. (Londrina) ; 25(1): 02-09, 20230330.
Article in English | LILACS-Express | LILACS | ID: biblio-1510041

ABSTRACT

Esse estudo propectivo teve como objetivo realizar a avaliação das alterações dentoalveolares em modelos digitais de pacientes cuja mordida aberta anterior foi tratada seguindo dois protocolos distintos: esporão lingual e mentoneira. A amostra foi composta por 41 pacientes (27 do sexo feminino e 14 do sexo masculino) com idades entre 7-10 anos (média de idade de 8.37 anos), dentição mista com diagnóstico de mordida aberta anterior (média de -3.43mm) e tratados ao longo de um ano. Os pacientes foram aleatoriamente dividiso em dois grupos de acordo com a terapia realizada: Grupo 1 (n=23) tratados com esporão lingual, e Grupo 2 (n=18) tratados com mentoneira pré-fabricada. Os modelos de gesso foram escaneados, gerando uma imagem tridimensionao em qual as medidas foram realizadas em 2 tempos distintos: T1 (imediatamente antes do tratamento) e T2 (um ano após o início do tratamento). Alteraçnoes transversais, comprimento e perímetro dos arcos dentários superior e inferior, trespasse horizontal e vertical, assim como inclinação dos incisivos centrais foram avaliadas. O Coeficiente de Correlação Interclasse (CCI) e o método Bland-Altman foram aplicados para verificar o erro intra examinador. Os resultados foram analisados através do Teste T pareado e independente adotando uma significância de 5%. Após um ano de tratamento, observou-se alerações estatisticamente significantes em todas as variáveis, exceto perímetro e comprimento dos arcos superio e inferior, inclinação do incisivo central superior e trespasse horizontal. As alterações enre os grupos (T2-T1) apresentaram resultados similares. Concluiu-se que ambos os protocolos apresentaram mudanças semelhantes na mordiada aberta anterior após um ano de tratamento.(AU)

3.
RGO (Porto Alegre) ; 71: e20230002, 2023. tab
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1422498

ABSTRACT

ABSTRACT Context: Digital study models have become a safe and advantageous alternative for diagnosis and planning in dentistry. Despite the superior characteristics in comparison with traditional plaster models, professionals seem to resist the use of new technologies. Aims: To assess the level of knowledge and the use of digital models through a questionnaire applied to dental professionals. Methods: A questionnaire with 12 multiple-choice questions about plaster models, digital, and use of the 3Shape - 3D viewer software was answered by 76 orthodontists (42 women and 34 men; mean age =37.82 years (SD ± 7.60)) and 30 general dental surgeons (18 women and 12 men; mean age of 33.93 years (SD ± 8.45)) in Aracaju, Sergipe, Brazil. Data were tabulated in Excel spreadsheets and then analyzed using the SPSS statistical software version 20. An absolute analysis of frequency and percentage of responses was performed. Results: Most professionals reported using plaster models and claimed their low cost as justification for their use (P = 0.001). Aware of the benefits of digital models, professionals of both classes highlighted the facilitated storage and search for information as the main advantages, the cost and infrastructure as the main disadvantages. Regarding the use of the 3Shape - 3D viewer software, orthodontists showed better utilization of this resource than general dental surgeons (P = 0.0198). Conclusion: It verified that most professionals make use of plaster models. However, despite knowing the advantages of digital models, their cost is sees as a limiting factor for adherence to this technology.


RESUMO Contexto: Os modelos digitais de estudo têm se tornado uma alternativa segura e vantajosa para o diagnóstico e planejamento em odontologia. Apesar das características superiores em comparação aos modelos tradicionais de gesso, os profissionais parecem resistir ao uso de novas tecnologias. Objetivos: Avaliar o nível de conhecimento e a utilização de modelos digitais por meio de questionário aplicado a profissionais da área odontológica. Material e Métodos: Questionário com 12 questões de múltipla escolha sobre modelos de gesso, digitais e uso do software 3Shape - 3D viewer foi respondido por 76 ortodontistas (42 mulheres e 34 homens; idade média = 37,82 anos (DP = ± 7,60) ) e 30 cirurgiões-dentistas gerais (18 mulheres e 12 homens; média de idade de 33,93 anos (DP = ± 8,45)) em Aracaju, Sergipe, Brasil. Os dados foram tabulados em planilhas do Excel e posteriormente analisados no software estatístico SPSS versão 20. Foi realizada uma análise absoluta de frequência e percentual de respostas. Resultados: A maioria dos profissionais relatou utilizar modelos de gesso e alegou seu baixo custo como justificativa para seu uso (P = 0,001). Cientes dos benefícios dos modelos digitais, os profissionais de ambas as classes destacaram o armazenamento facilitado e a busca de informações como as principais vantagens, o custo e a infraestrutura como as principais desvantagens. Em relação à utilização do software 3Shape - 3D viewer, os ortodontistas apresentaram melhor aproveitamento desse recurso do que os cirurgiões-dentistas gerais (P = 0,0198). Conclusões: Verificou-se que a maioria dos profissionais faz uso de modelos de gesso. Porém, apesar de conhecer as vantagens dos modelos digitais, seu custo é visto como um fator limitante para a adesão a essa tecnologia.

4.
Natal; s.n; 25 fev. 2022. 36 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1532963

ABSTRACT

O objetivo deste estudo laboratorial foi avaliar a acurácia dos modelos digitais obtidos por duas técnicas de escaneamento (escâner intraoral - Itero 5d Element® - e escâner de bancada -Straumann ®) de um modelo experimental (Nacional Ossos ®) da arcada superior confeccionada em poliuretano e do modelo de gesso obtido desta arcada. Os pontos A ­ 3mm acima do elemento 17; B ­ 3mm acima do elemento 14; C ­ 3mm acima do elemento 24; D ­ 3mm acima do elemento 27; E ­ cúspide mesiovestibular do elemento 16; F - ponto de contato mais incisal entre os elementos 11 e 21; G - Cúspide mesiovestibular do elemento 26 foram utilizados como referência para as medidas realizadas. As medidas foram realizadas em um software (Geomagic®) de simulação cirúrgica e analisadas quanto a validade e precisão das técnicas de escaneamento utilizadas em todos os grupos (1 a 5). O grupo 1 corresponde ao grupo padrão-ouro; o 2 ao grupo do escaneamento com escâner intraoral do modelo de poliuretano; o 3 ao escaneamento de bancada do modelo; o 4 ao escaneamento com escâner intraoral do modelo de gesso; e 5 ao escaneamento de bancada do modelo de gesso. Na análise da validação, todas as técnicas apresentaram-se válidas quando comparadas ao grupo controle com exceção da medida FG que apresentou diferenças estatisticamente significativas (p<0,05) entre os grupos 1 e 2. A precisão foi avaliada através do índice de correlação intraclasse (CCI) e todas as técnicas apresentaram-se altamente precisas com (CCI) próximo de 1. Desta forma, conclui-se que o escâner intraoral e o escâner de bancada utilizados neste estudo foram confiáveis quando comparados ao grupo controle e que os dois modelos de escâner utilizados se apresentaram com alta precisão (AU).


The objective of this experimental study was to evaluate the accuracy of digital models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. Points A ­ 3mm above element 17; B ­ 3mm above element 14; C ­ 3mm above element 24; D ­ 3mm above element 27; E ­ mesiobuccal cusp of element 16; F - most incisal point of contact between elements 11 and 21; G - Mesiobuccal cusp of element 26 were used as a reference for the measurements performed. The measurements were performed in a surgical simulation software (Geomagic ®) and analyzed for the validity and precision of the scanning techniques used in all groups (1 to 5). Group 1 corresponds to the gold standard group; 2 to the scanning group with intraoral scanner of the polyurethane model; 3 to the desktop scan of the model; 4 to intraoral scanner scanning of the plaster model; and 5 to the desktop scan of the plaster model. In the validation analysis, all techniques showed to be valid compared to the control group, except the FG measure, which showed statistically significant differences (p<0.05) between groups 1 and 2. Precision was assessed using the intraclass correlation(ICC) index, and all techniques were highly accurate with an ICC close to 1. Thus, it is concluded that the intraoral scanner and the bench scanner used in this study were reliable compared to the control group and that the two scanner models used presented themselves with high precision (AU).


Subject(s)
Imaging, Three-Dimensional/instrumentation , Models, Dental/trends , Orthognathic Surgery , Dimensional Measurement Accuracy , Statistics, Nonparametric , Clinical Laboratory Techniques
5.
Dental press j. orthod. (Impr.) ; 27(1): e2219388, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1364782

ABSTRACT

ABSTRACT Introduction: Currently, no method is considered effective for the evaluation of digital models in the Certification Examination of the Brazilian Board of Orthodontics (BBO), considering the parameters of the currently used manual method. Objective: Thus, the aim of this study is to verify the reliability of an evaluation method for digital models that could be used in the BBO exam, compared to the gold standard. Methods: Measurements were performed by five previously calibrated examiners. Samples of ten sets of plaster models of the final phase of orthodontic treatment were measured using a manual method (Objective Grading System, OGS). These models were digitized using a 3D scanner and exported to Geomagic Qualify software, in which the measurements were made with the proposed digital method. These measurements were repeated using five models, after fifteen days. The intra-examiner performance with this method was analyzed with a paired t-test, whereas the inter-examiner analysis was carried out with analysis of variance and Tukey's test. To compare the manual and digital methods, a paired t-test and Pearson's correlation analysis were performed. Results: A statistically significant difference was found. The results showed that, when compared to the manual method, the digital method was effective in measuring the OGS in four of the seven variables studied: Marginal Ridge, Overjet, Occlusal Contact, and Interproximal Contact. The variables Alignment, BL inclination, and Occlusal Relationship showed a great amount of dispersion in the findings. Conclusion: Further studies are needed to develop an adequate digital methodology that can be used for all OGS variables.


RESUMO Introdução: Ainda não há um método considerado eficaz para análise dos modelos digitais no exame do Board Brasileiro de Ortodontia (BBO), considerando-se os parâmetros do método manual atual. Objetivo: Assim, o presente estudo objetiva verificar a confiabilidade de um método de avaliação em modelos digitais para o exame do BBO, comparando com o padrão-ouro. Métodos: As medições foram realizadas por 5 examinadores, previamente calibrados. A amostra de 10 pares de modelos de gesso da fase final do tratamento ortodôntico foi medida no método manual (Sistema Objetivo de Avaliação, SOA). Os modelos foram digitalizados por meio de um scanner 3D e exportados para o software Geomagic Qualify, onde foram feitas as medidas no método digital proposto. As medidas foram refeitas em 5 modelos após 15 dias. A análise intraexaminador desse método foi realizada por meio do teste t pareado; já a interexaminadores, feita com ANOVA e teste de Tukey, sendo encontrada diferença estatisticamente significativa. Para a comparação dos métodos manual e digital, foram utilizados o teste t pareado e a correlação de Pearson. Resultados: Uma diferença estatisticamente significativa foi encontrada. Os resultados mostraram que, comparada ao método manual, a metodologia digital mostrou-se eficaz para medição do SOA em quatro das sete variáveis estudadas: Margem interproximal, Sobressaliência, Contato oclusal e Contato interproximal. As variáveis Alinhamento, Inclinação V-L e Relação oclusal mostraram muita dispersão nos achados. Conclusão: Mais estudos são necessários para o desenvolvimento de uma metodologia digital adequada em todas as variáveis do SOA.


Subject(s)
Orthodontics , Software , Pilot Projects , Reproducibility of Results , Models, Dental
6.
Dental press j. orthod. (Impr.) ; 26(3): e2119148, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1286208

ABSTRACT

ABSTRACT Objective: The objectives of the present study were to develop a method for longitudinally measuring tooth rotation, inclination and angulation on digital models, and to test the method validity and reliability. Methods: The initial and final planned models of 14 patients treated with Invisalign® (386 teeth) were exported from ClinCheck®. The rotation, inclination and angulation values were assessed for the incisors, canines, premolars and molars, in both models, using trigonometry. An application was developed in Python 2.7 to automate the measurements. The ∆planned (variation in the position between the initial and final planned models) was obtained for each tooth and each type of movement. To test the validity, the degree of agreement between the ∆planned and the values available in the Invisalign® Table of Movements was assessed using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis. For intra and inter-rater reliabilities, the ∆planned was obtained again. Results: Excellent ICCs (> 0.9) and limits of agreement with narrow and clinically acceptable discrepancies were obtained for the rotation of all teeth (except maxillary canines, which had broader limits: -3.47 - 5.43) and for the inclination of premolars and molars. The inclination of anterior teeth and angulation of all teeth had ICCs and limits that were not indicative of great agreement. The reliability was high for the three movements (discrepancy <2°). Conclusions: The method developed is reliable and suitable for longitudinally measuring inclination (posterior teeth) and rotation (except maxillary canines). It has limited value for the other movements measurements.


RESUMO Objetivo: Os objetivos do presente estudo foram desenvolver um método para medir longitudinalmente a rotação, inclinação e angulação dentárias em modelos digitais, e testar sua validade e reprodutibilidade. Material e Métodos: Os modelos inicial e final planejado de 14 pacientes tratados com Invisalign® (386 dentes) foram exportados do ClinCheck®. Os valores de rotação, inclinação e angulação foram calculados para incisivos, caninos, pré-molares e molares, em ambos os modelos, por meio de trigonometria. Um aplicativo desenvolvido em Python 2.7 foi utilizado para automatização das medidas. O ∆planejado (variação na posição entre os modelos inicial e final planejado) foi obtido para os movimentos descritos, nos diferentes grupos de dentes. A validade do método foi verificada pelo grau de concordância entre o ∆planejado e os valores disponíveis na Tabela de Movimentos do Invisalign®, utilizando-se o Coeficiente de Correlação Intraclasse (ICC) e a análise de Bland-Altman. O ∆planejado foi novamente calculado para análise da reprodutibilidade intra e interexaminadores. Resultados: Excelentes ICCs (> 0,9) e limites de concordância com discrepâncias reduzidas e clinicamente aceitáveis foram obtidos para a rotação de todos os dentes (exceto os caninos superiores, que expressaram limites mais amplos: -3,47 - 5,43) e para a inclinação de pré-molares e molares. A inclinação dos dentes anteriores e a angulação de todos os dentes apresentaram ICCs e limites não representativos de boa concordância. A reprodutibilidade foi alta para os três movimentos (discrepância < 2°). Conclusões: O método desenvolvido é reprodutível e se mostrou adequado para mensuração longitudinal da inclinação de dentes posteriores e rotação de todos os dentes, exceto caninos superiores. Apresenta valor limitado para as demais mensurações.


Subject(s)
Humans , Tooth Movement Techniques , Cuspid , Bicuspid , Reproducibility of Results , Incisor
7.
Acta odontol. latinoam ; 33(3): 221-227, Dec. 2020. graf
Article in English | LILACS | ID: biblio-1278208

ABSTRACT

ABSTRACT The aim of this study was to evaluate the precision and accuracy of molds made with four commercial brands of alginate scanned at different times using digital model analysis. Eighty molds of a standard Typodont were made using 4 types of alginate (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 and JP: Jeltrate Plus). The molds were scanned at four times: immediately (T1), 24h (T2), 72h (T3) and 120h (T4) after molding. Measurements were taken in three dimensions: anteroposterior, transverse and vertical. Significant differences in dimensional changes were noted between the materials over time (p <0.05). Anteroposterior dimensional variation was noted between times, especially for IA and JP. For transverse and vertical variables, a difference was found between the groups, especially at 24 h, 72 h and 120 h. CCC presented significant dimensional shrinkage only at T120 (transverse). IA and JP presented larger dimensional distortions in the vertical measurements. The molding materials used were not dimensionally stable when evaluated after 120 hours of molding. However, such evidence suggests that alginates with longer storage time, such as Cavex Color Change, are more accurate than conventional alginates.


RESUMO O objetivo do presente estudo foi avaliar a precisao e acurácia por meio de análise de modelos digitais de moldes digitalizados obtidos com quatro marcas comerciais de alginato em diferentes tempos. Oitenta moldes de um Typodont padrao foram obtidos utilizando 4 tipos de alginato (CCC: Cavex Color Change; IA: Identic Alginate; HY5: Hydrogum 5 e JP: Jeltrate Plus). Os moldes foram escaneados em quatro tempos: mediatamente (T1), 24h (T2), 72h (T3) e 120h (T4) após a moldagem. As medidas foram feitas em très dimensoes: ântero-posterior, transversal e vertical. Diferenças significativas nas mudanças dimensionais foram observadas entre os materiais ao longo do tempo (p <0,05). Variação dimensional ântero-posterior foi observada entre os tempos, principalmente para IA e JP. Para as variáveis transversal e vertical houve diferenga entre os grupos, principalmente em 24h, 72h e 120h. CCC apresentou contração dimensional significativa apenas em T120 (transversal). IA e JP apresentaram maiores distorções dimensionais na vertical. Os materiais de moldagem utilizados nao foram dimensionalmente estáveis quando avaliados após 120 horas de moldagem. No entanto, tais evidencias sugerem que os alginatos com maior tempo de armazenamento, como Cavex Color Change, sao mais precisos do que os alginatos convencionais.


Subject(s)
Humans , Dental Impression Materials/chemistry , Models, Dental , Alginates/chemistry , Materials Testing , Dental Impression Technique
8.
Acta odontol. latinoam ; 33(1): 3-5, June 2020. graf
Article in English | LILACS | ID: biblio-1130725

ABSTRACT

ABSTRACT The aim of this study was to compare the accuracy and precision of 3D printers used to obtain models of fixed dental prostheses. A fixed dental prosthesis preparation was scanned and reproduced by four 3D printers: RapidShape P40, Asiga MAX, Varseo, and Photon. The impressions were scanned again, and the dataset was compared to the original dataset. Mean discrepancies (μm) were 52.97±20.48 (RapidShape P40), 68.27±43.53 (Asiga MAX), 62.22±56.21 (Varseo), and 80.03±28.67 (Photon). There was no difference (p=0.314) in accuracy; however, the precision differed (p=0.015) among the 3D printers. The printers had distinct precision but did not differ in accuracy.


RESUMO O objetivo desse trabalho foi comparar a acurácia e a precisão de impressoras 3D utilizadas para a obtenção de modelos para prótese fixa. Um preparo para prótese fixa foi escaneado e reproduzido por 4 impressoras 3D: RapidShape 3D, Asiga MAX, Varseo e Photon. As impressões foram novamente escaneadas, e o dataset escaneado foi comparado ao original. Os esca neamentos foram sobrepostos digitalmente e determinada a discrepância entre os modelos original e impresso. A discre pância média (μm) entre os modelos foi de foi 52,97±20,48 (RapidShape 3D), 68,27±43,53 (Asiga MAX), 62,22±56,21 (Varseo) e 80,03±28,67 (Photon). Não houve diferença (p=0,314) entre os valores médios, os quais representam a acurácia; entretanto, o desvio padrão dessas foi diferente (0,015), indicando diferença na precisão das impressoras 3D.


Subject(s)
Humans , Dental Prosthesis , Models, Dental , Printing, Three-Dimensional/standards
9.
Dental press j. orthod. (Impr.) ; 24(1): 37e1-37e9, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-989688

ABSTRACT

ABSTRACT Introduction: Palatal rugae complete its development during early intrauterine life, whereas dental malocclusions in permanent dentition establishes several years into the post-natal life. Objective: The objective of present study was to determine if there is an association between the palatal rugae pattern and Angle's classes of malocclusion. Methods: A cross-sectional study was conducted on pretreatment dental casts of 184 patients. The sample was divided into the following groups: Class I, Class II div. 1, Class II div. 2, and Class III. The number of palatal rugae was recorded, bilaterally. The length, pattern and orientation of three anterior-most primary rugae on both sides were recorded. Results: The mean age of the study sample was 17.8 ± 5.4 years. The mean number of the palatal rugae was 11.18 ± 2.5, with significant differences among different malocclusion groups. The length of the first rugae on left side and third rugae on both sides varied significantly among the groups (p< 0.05). Similarly, the pattern of palatal rugae was also found to be significantly different among the malocclusion groups. The right sided rugae did not have any significant difference in the orientation in different malocclusion groups; however, the left sided rugae showed significant differences among the four malocclusion groups (p< 0.001). Conclusions: The current study showed subtle differences in the palatal rugae pattern among the Angle's classes of malocclusion. Similarly, the length and orientation of some rugae were also found to be significantly different between malocclusion groups.


RESUMO Introdução: as rugas palatinas completam seu desenvolvimento ainda no início da vida intrauterina, enquanto as más oclusões dentárias na dentição permanente se estabelecem após vários anos de vida pós-natal. Objetivos: o presente estudo foi planejado para determinar se há associação entre o padrão das rugas palatinas e as más oclusões, segundo a classificação Angle. Métodos: um estudo transversal foi conduzido a partir dos modelos dentários pré-tratamento de 184 pacientes. A amostra foi dividida em quatro grupos: Classe I; Classe II, divisão 1; Classe II, divisão 2 e Classe III. O número de rugas palatinas foi registrado bilateralmente. O comprimento, padrão e a orientação das três rugas primárias mais anteriores de ambos os lados foram registrados. Resultados: a idade média da amostra desse estudo foi de 17,8 ± 5,4 anos. O número médio de rugas palatinas foi de 11,18 ± 2,5, com diferenças significativas entre os grupos de más oclusões. O comprimento da primeira ruga do lado esquerdo e da terceira ruga em ambos os lados variou significativamente entre os grupos (p< 0,05). De forma semelhante, o padrão das rugas palatinas também mostrou diferença significativa entre os grupos com diferentes má oclusões. As rugas do lado direito não apresentaram nenhuma diferença significativa de orientação nos diferentes grupos; no entanto, as rugas do lado esquerdo apresentaram diferenças significativas nos grupos estudados (p< 0,001). Conclusões: o presente estudo demonstrou diferenças sutis quanto ao padrão das rugas palatinas entre as classes de má oclusão definidas por Angle. Do mesmo modo, o comprimento e a orientação de algumas rugas também se apresentaram consideravelmente diferentes entre os grupos com diferentes má oclusões.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Palate, Hard/anatomy & histology , Malocclusion , Mouth Mucosa/anatomy & histology , Cross-Sectional Studies
10.
J. health sci. (Londrina) ; 20(2)30/06/2018.
Article in English | LILACS | ID: biblio-909318

ABSTRACT

Alginate is among the most used materials in dentistry to create teeth negative printing and reproduction. The goal of this study was to compare dimensional changes of alginate scanned impression materials. Thirty impressions of a standard typodont were performed using three types of alginate (Hydrogum 5; Jeltrate Plus and Avagel). The impressions were scanned by the scanner 3Shape R700T and scans were performed immediately after molding. The analysis of digital models were performed at OrthoAnalyzer ™ 3D software. Measurements were carried out in relation to the transverse dimension (intercanine, interpremolares and intermolar). Method error was evaluated through the Intraclass Correlation Coefficient (ICC) and Bland-Altman. One-way ANOVA, Dunnet Post-test were used to compare the different groups in relation to Typodont (gold standard) for the different outcome variables. The data were tabulated in Statistical Package for Social Sciences version 20.0 and Minitab 17.0 softwares to compare groups. The significance level was 5%. The posterior transverse variables (D1PM, D2PM and DM) presented a statistically significant difference regarding the gold standard (Typodont) for the plaster models performed after the Avagel molding. In the digital models performed just after molding, only in DM, the Avagel material group presented values statistically higher than the control group. The alginates Hydrogum 5 and Jeltrate Plus presented dimensions closer to the gold standard.(AU).


O alginato está entre os materiais de moldagem mais utilizados na Odontologia para criar impressão e reprodução negativa dos dentes. O objetivo desse trabalho foi comparar alterações transversais de três marcas comerciais de alginato (Hydrogum, Jeltrate e Avagel) em moldes de alginatos. Trinta moldes de um Typodont padrão foram realizados, utilizando três tipos de alginato (Hydrogum 5; Jeltrate Plus e Avagel). Os moldes foram escaneados por meio do scanner 3Shape R700T e os escaneamentos realizados logo após a moldagem e logo após a obtenção dos modelos de gesso. As análises dos modelos digitais foram realizadas no software OrthoAnalyzer™ 3D. Foram realizadas mensurações em relação à discrepância transversal (inter-caninos, inter-primeiro pré-molar, inter-segundo pré-molar e inter-molares). O erro do método foi avaliado por meio do Coeficiente de Correlação Intraclasse (CCI) e Bland-Altman. Utilizou-se Análise de Variância (one-way ANOVA, Pós-teste Dunnet) para comparação dos diferentes grupos em relação ao typodont (padrão-ouro) para as diferentes variáveis de desfecho. A análise estatística foi realizada nos programas Statistical Package for Social Sciences versão 20.0 e no programa Minitab 17.0 para comparação dos grupos. O nível de significância foi de 5%. As variáveis transversais posteriores (D1PM; D2PM e DM) apresentaram diferença estatisticamente significante em relação ao padrão-ouro (manequim) para os modelos de gesso realizados após a moldagem com Avagel. Nos modelos digitais realizados logo após a moldagem, apenas na DM, o grupo do material Avagel apresentou valores estatisticamente maiores do que o grupo controle. Os alginatos Hydrogum 5 e Jeltrate Plus apresentaram dimensões mais próximas do padrão-ouro.(AU).

11.
HU rev ; 44(1): 97-113, 2018.
Article in Portuguese | LILACS | ID: biblio-986572

ABSTRACT

Introdução: Os modelos ortodônticos digitais são alternativas ao uso de modelos ortodônticos em gesso. Devido sua importância no diagnóstico, faz-se necessário averiguar a precisão dos softwares de modelos ortodônticos digitais disponíveis no mercado. Objetivo: Evidenciar qual software de modelos ortodônticos digitais possui maior confiabilidade. Material e métodos: Foi realizada busca sistemática nas seguintes bases de dados eletrônicas: Scopus, PubMed, Web of Science, Embase e Cochrane, Grey Literature e Clinical Trials, sem limitações quanto ao ano de publicação ou idioma. Foram incluídos estudos laboratoriais que utilizaram softwares destinados a geração de modelos ortodônticos digitais, comparando-os com modelos ortodônticos em gesso. Após seleção por título e resumo, os artigos potencialmente elegíveis foram lidos na íntegra. A qualidade metodológica e o risco de viés dos artigos incluídos foram avaliados de acordo com as descrições dos modelos, técnicas de medição e análises estatísticas. A qualidade metodológica foi classificada em alta, moderada ou baixa. Resultados: 13.333 artigos foram encontrados nas bases de dados utilizadas. Após a aplicação dos critérios de elegibilidade e remoção de duplicações, restaram apenas 41 artigos. 29 foram considerados de qualidade moderada e 12 de alta qualidade. A classificação quanto à confiabilidade variou de menos confiaveis, equivalentes e a mais confiaveis. Apresentando diferenças estatisticas em suas mensurações (p<0,05); sem significância clínica. Conclusão: os modelos ortodônticos digitais apresentaram mensurações acuradas, reprodutíveis e confiáveis quando comparado ao método convencional utilizando modelos de gesso.


Introduction: Digital models are an alternative for the use of orthodontic models in plaster. Due to its importance in the orthodontic dignified, it is necessary to ascertain the accuracy of the software of digital orthodontic models available in the market. Objective: To show which software of digital orthodontic models has greater reliability. Material and methods: A systematic search was performed in the following electronic databases: Scopus, PubMed, Web of Science, Embase and Cochrane, Gray Literature and Clinical Trials, with no limitations on year of publication or language. We included laboratory studies using digital orthodontic models, comparing them with orthodontic models of plaster through the evaluation of reliability through measurement techniques. After selection by title and abstract, potentially eligible articles have been read in full. The methodological quality and risk of bias of the included articles were evaluated according to the descriptions of the models, measurement techniques and statistical analyzes. The methodological quality was classified as high, moderate or low. Results: 13,333 articles were found in the databases used. After applying the eligibility criteria and removing duplicates, only 41 articles remained. 29 were considered of moderate quality and 12 of high quality. The ranking of digital models for reliability ranged from less reliable, equivalent, and more reliable. Presenting statistical differences in their measurements (p <0.05), without clinical significance. Conclusion: The measurements made in digital models can be as accurate, reproducible and reliable as the conventional method using plaster models.


Subject(s)
Orthodontics , Models, Dental , Software , Imaging, Three-Dimensional
12.
Bauru; s.n; 2018. 62 p. ilus, tab.
Thesis in English | LILACS, BBO | ID: biblio-905295

ABSTRACT

This study aimed to present two papers that show the alterations in the dental arch dimensions of children with cleft lip and palate before and after the primary surgeries. The first study aimed to evaluate the dimensional alterations of the dental arches of neonates with unilateral complete cleft lip and palate before and after two different primary plastic surgeries. The sample was composed of 114 dental casts of 57 children, divided into two groups: Group 1 ­ 26 neonates whose lip closure was accomplished at 3 months of life by Millard´s technique and the anterior and posterior palate closure by von Langenback's technique (VL); Group 2 ­ 31 neonates whose lip closure, nose's ala correction, and anterior palate closure were accomplished of life by Millard´s technique, Mcomb's or Skoog's technique, and vomer's flap, respectively at 3 months of life; posterior palate closure was accomplished by VL at 12 months of life. The dental casts were analyzed at two phases: (T1) pre-cheiloplasty and (T2) one year after palatoplasty. The second study aimed to evaluate morphometrically and longitudinally the alterations of the dental arch dimensions of children with cleft lip and palate. The sample was composed by digital dental casts of children with complete cleft lip (Group 1), complete cleft lip and palate (Group 2), and complete cleft palate (Group 3), obtained at pre-cheiloplasty (T1), pre-palatoplasty (T2), and one year after palatoplasty (T3). The measurements of the dental arch dimensions of both studies were performed directly on the digitized models and analyzed by Appliance Designer software. The following dimensions were obtained: intercanine distance, inter-tuberosity distance, anterior arch length, and total arch length. A previously trained and calibrated examiner performed the assessments of both studies. To verify the alterations among groups, t test and ANOVA followed by Tukey was applied. In the first study, no statistically significant differences occurred at pre-cheiloplasty. At one year after palatoplasty, Group 1 had statistically significant greater anterior-posterior arch length (P=0.002) than Group 2. This suggested that the outcomes of the different surgical techniques may cause alterations in the dental arch growth and development of neonates with cleft lip and palate. In the second study, in Group 1, the distances C-C', T-T', and I-TT' were statistically greater at T2 than at T1. In Group 2, the distances C-C' and I-CC' were smaller at T3. T-T' distance decreased and I-TT' distance increased at all phases. In Group 3, the C-C', T-T', and I-TT' distances were statistically greater at T3. The intergroup comparisons showed that C-C' and T-T' distances were statistically greater in Group 1; C-C' and I-CC' distances were statistically smaller in Group 2; and I-TT' distance was statistically greater in Group 3. The longitudinal evaluation of the changes occurred in the dental arches of children with different oral cleft types showed that cheiloplasty and palatoplasty caused the most alterations in the growth and development of the maxillary dimensions of children with complete cleft lip and palate.(AU)


O propósito deste estudo foi apresentar dois artigos que mostram as alterações das dimensões dos arcos dentários de crianças com fissura labiopalatina antes e depois das cirurgias primárias. O primeiro estudo foi proposto para avaliar as alterações dimensionais dos arcos dentários de neonatos com fissura labiopalatina antes e após a realização de duas técnicas distintas de cirurgias plásticas primárias. A amostra foi composta de 114 modelos dentários em gesso de 57 crianças, divididos em dois grupos: Grupo I ­ 26 neonatos, fechamento do lábio realizado aos 3 meses de vida pela técnica de Millard e palato total aos 12 meses, pela técnica de von Langenback (VL); Grupo II ­ 31 neonatos, fechamento do lábio pela técnica de Millard aos 3 meses de vida, correção de asa nasal (técnicas de Mcomb ou Skoog) e palatoplastia anterior com retalho de vômer aos 3 meses. A palatoplastia posterior foi realizada aos 12 meses pela técnica VL. Os modelos foram analisados em 2 fases: (F1) pré-queiloplastia e (F2) 1 ano pós-palatoplastia. No segundo estudo o objetivo foi realizar uma avaliação longitudinal das alterações das dimensões dos arcos dentários de crianças com fissura labiopalatina. A amostra foi composta de modelos digitais de crianças com fissura completa de lábio (Grupo 1), completa de lábio e palato (Grupo 2), e completa de palato (Grupo 3), obtidos nas fases de pré-queiloplastia (Fase 1), pré-palatoplastia (Fase 2), 1 ano póspalatoplastia (Fase 3). As medidas das dimensões dos arcos dentários nos dois estudos foram realizadas nos modelos digitalizados e analisados utilizando software Appliance Designer. As seguintes dimensões foram obtidas: distância intercaninos, distância intertuberosidade, comprimento anterior do arco dentário e comprimento total do arco. Um avaliador previamente calibrado e treinado realizou as avaliações para os dois estudos. Foi aplicado o Teste t e a Análise de Variância, seguida do Teste de Tukey. Para o primeiro estudo não houve diferença estatisticamente significante na fase pré-queiloplastia entre os grupos. Na fase 1 ano pós-palatoplastia houve diferença para o comprimento anteroposterior do arco dentário (p=0,002), entre os grupos, com valores maiores para o grupo I. Para o segundo estudo, no Grupo 1, as distâncias C-C', T-T' e I-TT' apresentaram diferença estatisticamente significante entre a F1 e F2, com aumento na F2. Para o Grupo 2, houve diferença estatisticamente significante em todas as fases avaliadas. As distâncias C-C' e I-CC' apresentaram menor valor na F3, T-T' diminuiu em todas as fases, e I-TT' aumentou em todas as fases. No Grupo 3, as distâncias C-C', T-T' e I-TT' mostraram diferença estatisticamente significante com aumento na F3. Quando avaliadas as medidas entre os grupos e fases, C-C' e T-T' mostraram um valor maior para o Grupo 1. A comparação entre F2 e F3 mostraram para as distâncias C-C' e I-CC' valor menor para o Grupo 2, e I-TT' foi maior para o Grupo 3. As avaliações longitudinais nos arcos dentários mostraram que a queiloplastia e palatoplastia causam maiores alterações de crescimento e desenvolvimento maxilares de pacientes com fissura completa de lábio e palato.(AU)


Subject(s)
Humans , Animals , Male , Infant , Child, Preschool , Cleft Lip/pathology , Cleft Palate/pathology , Dental Arch/pathology , Anatomic Landmarks , Cleft Lip/surgery , Cleft Palate/surgery , Models, Dental , Imaging, Three-Dimensional , Longitudinal Studies , Reference Values , Sex Factors
13.
Dental press j. orthod. (Impr.) ; 22(6): 68-73, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-891114

ABSTRACT

ABSTRACT Introduction: Plaster dental casts are routinely used during clinical practice to access maxillary dental arch form and assist on fabrication of individualized orthodontic archwires. Recently introduced, digital model technology may offer a limitation for the obtainment of a dental physical record. In this context, a tool for dental arch form assessment for chairside use is necessary when employing digital models. In this regard, paper print of the dental arch seems thus to be useful. Methods: In the present study, 37 lower arch models were used. Intercanine and intermolar widths and dental arch length measurements were performed and compared using plaster dental casts, digital models and paper print image of the models. Ortho Insight 3D scanner was employed for model digitalization. Results: No statistically significant differences were noted regarding the measurements performed on the plaster or digital models (p> 0.05). Paper print images, however, showed subestimated values for intercanine and intermolar widths and overestimated values for dental arch length. Despite being statistically significant (p< 0.001), the differences were considered clinically negligible. Conclusion: The present study suggests that paper print images obtained from digital models are clinically accurate and can be used as a tool for dental arch form assessment for fabrication of individualized orthodontic archwires.


RESUMO Introdução: os modelos de gesso são usados rotineiramente, durante a prática clínica, para avaliação da forma da arcada inferior e para auxiliar na confecção de arcos ortodônticos individualizados. A tecnologia dos modelos digitais, introduzida recentemente, pode oferecer uma limitação na obtenção de um registro físico da arcada dentária. Assim, quando se utilizam modelos digitais, faz-se necessária uma ferramenta clínica para obtenção da forma da arcada. Com essa finalidade, poderia-se imprimir, em papel, uma imagem da arcada dentária obtida a partir do modelo de gesso. Métodos: nesse estudo, 37 modelos da arcada inferior foram utilizados, nos quais foram realizadas medições das distâncias intercaninos, intermolares e comprimento da arcada; sendo, então, comparadas entre modelos de gesso, modelos digitalizados com um scanner Ortho Insight 3D e imagens impressas em folha de papel A4. Resultados: não foram encontradas diferenças estatisticamente significativas nas medidas realizadas nos modelos de gesso e modelos digitais (p > 0,05). As imagens impressas, contudo, mostraram valores subestimados para as distâncias intercaninos e intermolares, e superestimados para o comprimento da arcada. Apesar de serem estatisticamente significativas (p< 0,001), as diferenças foram consideradas clinicamente insignificantes. Conclusão: o presente estudo sugere que as imagens obtidas por meio dos modelos digitais e impressas em papel são clinicamente acuradas e podem ser utilizadas como uma ferramenta auxiliar na confecção dos arcos ortodônticos individualizados.


Subject(s)
Humans , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Dental Arch/anatomy & histology , Dental Arch/diagnostic imaging , Models, Dental , Mandible/anatomy & histology , Orthodontics/instrumentation , Orthodontics/methods , Software , Casts, Surgical , Reproducibility of Results , Analysis of Variance , Dental Impression Technique , Technology, Dental , Copying Processes , Printing, Three-Dimensional , Mandible/diagnostic imaging , Models, Anatomic
14.
Rev. Odontol. Araçatuba (Impr.) ; 38(3): 27-33, set.-dez. 2017. tab, graf, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-881656

ABSTRACT

Este é um estudo cuja finalidade foi demonstrar as possíveis deformações que podem ocorrer nos modelos obtidos de moldes de alginato, dependentes da forma de vazamento. Foram obtidos 20 moldes de alginato da marca Hydrogum 5 (Zhermack, Badia Polesine, Italy), através de um modelo de resina acrílica previamente preparado, divididos em dois grupos de 10: com vazamento invertido e não invertido. Os modelos foram analisados por fotografias, mensurados por um programa de computação (Corel Draw X3 Graphics Suíte (Corel Corporation ­ USA) e comparados com o modelo padrão. Os resultados mostraram que os vazamentos invertidos e não invertidos apresentaram valores clínicos diferentes do modelo padrão, mas que na comparação entre as técnicas, dos quatro segmentos analisados, apenas um apresentou diferença estatística significante(AU)


This is a study whose purpose was to demonstrate the possible deformations that may occur in the models obtained from alginate molds, depending on the form of flow. 20 alginate molds of Hydrogum 5 (Zhermack, Badia Polesine, Italy) were obtained through a previously prepared acrylic resin model, divided into two groups of 10: with inverted and non inverted casting. The models were analyzed by photographs, measured by a computer program (Corel Draw X3 Graphics Suite (Corel Corporation - USA) and compared with the standard model.The results showed that inverted and non inverted flow presented clinical values different from the standard model, But that in the comparison between the techniques, of the four analyzed segments, only one presented significant statistical difference(AU)


Subject(s)
Dental Impression Materials , Alginates
15.
Ortho Sci., Orthod. sci. pract ; 10(38): 45-48, 2017.
Article in Portuguese | LILACS, BBO | ID: biblio-837357

ABSTRACT

Modelos de estudo propiciam uma avaliação tridimensional dos arcos dentários superior e inferior, bem como da relação oclusal, sendo fundamentais ao diagnóstico e plano de tratamento de pacientes. Com o avanço da tecnologia e devido algumas desvantagens encontradas nos modelos tradicionais, a Ortodontia passou a empregar modelos digitais em que as análises antes realizadas com paquímetros são agora obtidas através de softwares. O presente estudo teve como objetivo avaliar a confiabilidade da análise de Bolton e da discrepância de modelos realizadas em modelos digitais. Quinze pares de modelos de gesso de pacientes foram selecionados e mesurados através de um paquímetro digital (Kingtools, São Paulo, Brasil, 150 mm, precisão 0,01 mm/.0005'). Posteriormente, os modelos foram escaneados pelo scanner Go Digital (Open Technologies, Itália). Para os respectivos modelos digitais obtidos, o software Maslab (Istituto di Scienza e Tecnologie de'll Informazione, Pisa, Itália) foi utilizado para medição. Todas as medidas e análises foram realizadas por um único examinador. Conduziu-se a análise estatística pelo software Graph Pad Prism 5.2 (GraphPad Software, Inc. Califórnia), e aplicou-se o teste de Mann Whitney, com intervalo de confiança de 95% e significância estabelecida em p<0,05.(AU)


Dental models provide a three-dimensional view of the upper and lower arches and the occlusal relationship, they are essential tools for the diagnosis and patient treatment plan. Due to technology advancement and some disadvantages found in traditional models, orthodontics started to use digital models (emodels) in which the analysis previously performed with calipers are now obtained through softwares. This study aimed to evaluate the reliability of Bolton analysis and the discrepancy of models performed in digital models. Fifteen pairs of patients plaster models were selected and measured with a digital caliper (Kingtools, São Paulo, Brazil, 150 mm, precision of 0,01 mm/.0005). The models were then scanned by Go Digital Scanner (Open Technologies, Italy). For the respective digital models obtained, Maslab software (Istituto di Scienza e Tecnologie de'll Informazione, Pisa, Italy) was used for measuring. All measurements and analyses were performed by a single examiner. The statistical analysis was conducted through the software Graph Pad Prism 5.2 (GraphPad Software, Inc. California) and the Mann-Whitney test was applied, with confidence interval of 95% and significance level of p<0,05. (AU)


Subject(s)
Models, Dental , Diagnosis, Computer-Assisted , Orthodontics
16.
Ortodontia ; 49(6): 558-658, nov.-dez 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-875260

ABSTRACT

Introdução: com a crescente utilização dos modelos digitais em Ortodontia, aumenta também a necessidade de se conhecer as opções disponíveis para sua obtenção. Atualmente, a alternativa mais utilizada é o escaneamento de modelos de gesso, que pode ser realizado em scanners a laser, por luz estruturada ou por tomografia computadorizada. O objetivo deste trabalho foi avaliar, através de uma análise por sobreposição de modelos digitais, a acurácia dos modelos digitais gerados por estes três métodos de escaneamento e a influência de dois diferentes níveis de resolução de escaneamento. Material e métodos: 30 pares de modelos de gesso foram escaneados utilizando as três tecnologias. O escaneamento por luz estruturada foi realizado com duas configurações do nível de resolução: máxima e padrão. Os modelos digitais gerados foram sobrepostos e as diferenças entre as superfícies foram calculadas. Mapas de cores foram utilizados para evidenciar as discrepâncias entre os modelos. Resultados: para todos os parâmetros avaliados, foram obtidas diferenças estatisticamente significantes. As diferenças entre os modelos escaneados a laser e por luz estruturada foram menores, o que sugere maior similaridade entre eles. Conclusão: as diferenças encontradas entre os modelos digitais obtidos pelas três tecnologias de escaneamento estudadas foram estatisticamente significantes. No entanto, por serem muito pequenas quantitativamente, não foram consideradas clinicamente significantes. Não houve diferença entre os dois níveis de resolução estudados, portanto, os três métodos de escaneamento avaliados possuem uma acurácia clinicamente aceitável para ser utilizado em Ortodontia.


Introduction: the increasing use of digital models in orthodontics demands knowledge of the available options for their acquisition. Currently, the most used option is the plaster model scanning, which can be made by laser, structured light and computed tomography scanners. The aim of this study was to evaluate, by a model superimposition analysis, the accuracy of digital models acquired by these three scanning methods and the influence of two different resolution levels of scanning. Methods: thirty pairs of plaster models were scanned using three different scanning technologies: laser, structured light and computed tomography. The structured light scanning was performed using two different resolution levels: maximum and standard. The respective digital models were superimposed and their mean differences were compared using color maps by Geomagic Qualify software. Results: for all parameters studied, statistically significant differences were found. Lower differences were presented between models scanned by laser and structured light techniques, which suggests a higher similarity between them. Conclusion: the differences found between digital models obtained by the three scanning technologies were statistically significant. However, they were quantitatively very small, which was considered clinically insignificant. There was no difference between the two resolution levels of scanning studied. Therefore the three scanning methods studied presented accuracy clinically acceptable to be used in orthodontics.


Subject(s)
Models, Dental , Dimensional Measurement Accuracy , Models, Dental/trends , Odontometry/methods
17.
Bauru; s.n; 2016. 123 p. tab, ilus.
Thesis in English | LILACS, BBO | ID: biblio-880935

ABSTRACT

Introdução: O objetivo do presente trabalho foi comparar os efeitos dentoesqueléticos do expansor com abertura diferencial (EAD) e do expansor Hyrax convencional em crianças na dentadura mista. Métodos: Quarenta e seis pacientes de ambos os sexos e com idades variando de 7 a 11 anos foram aleatoriamente alocados em um de dois grupos de estudo. O grupo experimental foi composto por 22 pacientes (idade média de 8,46 anos) que foram submetidos à expansão rápida da maxila (ERM) com o EAD. O grupo de comparação foi composto por 24 pacientes (idade média de 8,92) tratados com ERM utilizando-se o expansor Hyrax convencional. Fotografias foram obtidas imediatamente antes da expansão (T1) e ao término do período ativo da expansão maxilar (T2). Radiografias oclusais da maxila foram obtidas para cada paciente apenas ao término do período ativo da expansão maxilar (T2). Modelos digitais dos arcos dentários superior e inferior foram obtidos imediatamente antes da expansão (T1) e 6 meses pós-expansão (T3), na ocasião da remoção do aparelho. As variáveis de desfecho primário foram as alterações no diastema interincisal, a quantidade de abertura da sutura palatina mediana, as larguras dos arcos dentários superior e inferior, o perímetro dos arcos, o comprimento dos arcos, a profundidade do palato, a inclinação dos dentes pósterossuperiores e pósteroinferiores e a forma do arco dentário superior. A variável de desfecho secundário foi a quantidade de expansão diferencial nas regiões anterior e posterior do arco dentário superior. As comparações interfases e intergrupos foram realizadas por meio dos testes t pareado e testes t, respectivamente, com correção de Bonferroni para testes múltiplos. Resultados: Tanto o EAD quanto o expansor Hyrax convencional promoveram aumentos significantes do diastema interincisivos e da largura do arco dentário superior. Por outro lado, nenhuma diferença significante foi observada para a largura do arco dentário inferior de ambos os grupos de estudo. O EAD promoveu um aumento significante do perímetro do arco dentário superior e uma diminuição significante da profundidade do palato. De modo contrário, não foram observadas diferenças significantes para o perímetro do arco dentário inferior de nenhum dos dois grupos estudados. O comprimento do arco dentário superior diminuiu significantemente após a ERM com o expansor Hyrax, enquanto que o comprimento do arco inferior diminuiu suavemente no grupo do EAD. Ambos os expansores promoveram um aumento significante da inclinação vestibular dos dentes pósterossuperiores e dos caninos decíduos inferiores. O EAD promoveu aumentos significantemente maiores da dimensão da abertura da sutura palatina mediana, da largura do diastema interincisivos e das distâncias intercaninos, inter-primeiros molares decíduos e intersegundos molares decíduos superiores, quando comparado com o expansor Hyrax. Por outro lado, apenas o grupo de comparação apresentou um suave aumento da distância interprimeiros molares permanentes inferior. O grupo experimental apresentou uma expansão diferencial significantemente maior na região anterior quando comparada à região posterior do arco dentário superior, enquanto que o grupo de comparação promoveu quantidades de expansão similares na região dos caninos e dos primeiros molares permanentes superiores. Conclusões: Na dentadura mista, o expansor com abertura diferencial foi capaz de promover uma disjunção maxilar com uma maior abertura da região anterior da sutura palatina mediana. O EAD promoveu uma maior expansão da região anterior do arco dentário superior quando comparado com o expansor Hyrax convencional. Ambos os expansores se mostraram similares quanto à quantidade de expansão na região posterior do arco dentário superior, e para as alterações do perímetro dos arcos, comprimento dos arcos, profundidade do palato e inclinação dos dentes posteriores. Adicionalmente, pequenas alterações espontâneas do arco dentário inferior foram observadas para ambos os expansores, seis meses após a expansão rápida diferencial e convencional da maxila.(AU)


Introduction: The aim of this study was to compare the dentoskeletal effects of the expander with differential opening (EDO) and the conventional Hyrax expander in children in the mixed dentition. Methods: Forty-six patients of both sex and ages ranging from 7 to 11 years old were randomly allocated into two study groups. The experimental group comprised 22 patients (mean age of 8.46 years) who underwent rapid maxillary expansion (RME) with the EDO. The comparison group comprised 24 participants (mean age of 8.92 years) treated with RME using the conventional Hyrax expander. Photographs were obtained immediately pre-expansion (T1) and at the end of the active expansion phase (T2). Occlusal radiographs of maxilla were obtained for each patient at the end of the active expansion phase only (T2). Digital dental models of the maxillary and mandibular dental arches were obtained immediately preexpansion (T1) and 6 months post-expansion (T3), at the occasion of appliance removal. The primary outcomes were the interincisal diastema width change, the dimension of midpalatal suture opening, the maxillary and mandibular dental arch widths, the arches perimeter, the arches length, the palatal depth, the inclination of maxillary and mandibular posterior teeth and the maxillary dental arch shape. The secondary outcome was the amount of differential expansion in the anterior region compared to the posterior region of maxillary dental arch. Inter-phase and intergroup comparisons were performed using paired t tests and t tests, respectively, with Bonferroni correction for multiple tests. Results: Both the EDO and the conventional Hyrax expander promoted significant increases of the interincisal diastema width and of the maxillary dental arch widths. On the other hand, no significant differences were found for the mandibular dental arch widths of both groups. The EDO promoted a significant increase of the maxillary dental arch perimeter and a significant decrease of the palatal depth. On the other hand, no significant differences were found for the mandibular dental arch perimeter of both study groups. The maxillary dental arch length decreased significantly after RME with the conventional Hyrax expander. On the other hand, the mandibular dental arch length decreased slightly in the EDO group. Both expanders promoted a significant buccal inclination of the maxillary posterior teeth and mandibular deciduous canines. The EDO promoted significantly greater increases of the dimension of midpalatal suture opening, the width of interincisal diastema, the maxillary intercanine distance, the maxillary inter-first deciduous molars distance and the maxillary inter-second deciduous molars distance compared to the Hyrax expander. On the other hand, only the comparison group showed a slight decrease of the mandibular intermolar distance. The experimental group showed a significant differential expansion between the anterior and the posterior regions of the maxillary dental arch while the comparison group produced similar amount of expansion in the maxillary canine and in the maxillary molar regions. Conclusions: In the mixed dentition, the expander with differential opening was capable of producing an intermaxillary split with an increased dimension at the anterior limit of the midpalatal suture. The EDO promoted a greater expansion in the anterior region of the maxillary dental arch compared to the conventional Hyrax expander. Similarity between the two expanders was observed for posterior region expansion and for changes in arch perimeter, arch length, palatal depth and posterior teeth inclination. Additionally, small mandibular spontaneous dentoalveolar changes were observed for both expanders six months after differential and conventional rapid maxillary expansion.(AU)


Subject(s)
Humans , Male , Female , Child , Malocclusion, Angle Class II/therapy , Malocclusion, Angle Class I/therapy , Orthodontic Appliance Design , Orthodontic Appliances , Palatal Expansion Technique/instrumentation , Dental Arch/anatomy & histology , Reproducibility of Results , Statistics, Nonparametric , Treatment Outcome
18.
Rio de janeiro; s.n; 2016. 84 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1023240

ABSTRACT

Modelos dentários de gesso são muito utilizados tanto na prática quanto em pesquisa odontológica. Além de possuírem valor legal, eles auxiliam no diagnóstico e planejamento dos casos clínicos. No entanto, com o avanço das técnicas digitais, estes tendem a perder espaço para os modelos de estudo tridimensionais virtuais. A tecnologia digital tem sido muito utilizada, incluindo fotografias, radiografias, registros do tratamento realizado e modelos de estudo tridimensionais. O Board Americano de Ortodontia tem grande prestígio e reconhecimento na Ortodontia mundial e utiliza todos esses recursos digitais para avaliação das finalizações ortodônticas, com exceção dos modelos virtuais. Isso se deve ao fato de ainda não ter sido criada uma metodologia de avaliação de modelos virtuais relacionados ao final do tratamento ortodôntico satisfatória para os padrões do Board Americano. O objetivo deste estudo foi criar uma metodologia de análise de modelos digitais, compatível com o modelo de medição utilizado pelo Board Americano de Ortodontia, chamado "Objective Grading System". Para isso 30 modelos finais de tratamento ortodôntico foram medidos utilizando o método manual do Board Americano de Ortodontia e virtualmente através da digitalização dos mesmos pelo Dental Scanner (Pisa, Itália) e medidos no software Geomagic Qualify 2013.0.1:64 através de técnica de medição desenvolvida pelos autores. As metodologias foram comparadas utilizando o Teste t pareado e correlação de Pearson. A metodologia criada neste estudo parece ser uma alternativa viável para a avaliação do OGS em modelos digitais para 4 das 7 variáveis analisadas, sendo necessários mais estudos para adequação das metodologias de análise de modelos digitais e para a criação de softwares desenhados especificamente para este propósito.


Dental plaster models are widely used in clinical practice and dental research. Besides having legal value, they help in the diagnosis and treatment. However, with the improvement of digital techniques, they tend to lose ground to the three-dimensional virtual dental casts. Digital technology has been widely used, including photographs, radiographs, treatment records and three-dimensional dental casts. The American Board of Orthodontics is recognized by orthodontists in the whole world and uses digital resources for assessment of orthodontic submissions, with the exception of virtual final casts. This is because it has not been created a satisfactory methodology for evaluating virtual models related to the American Board of Orthodontics objective grading system. The aim of this study was to create a methodology for analysing digital models, compatible with the Objective Grading System. For this purpose, 30 final orthodontic casts were measured manually using the American Board of Orthodontics method and virtually by scanning the plaster casts in Dental Scanner (Pisa, Italy) and measuring in Geomagic Qualify software 2013.0.1: 64 through a measuring technique developed by the authors. The methods were compared using paired t test and Pearson's correlation. The methodology established in this study appears to be a viable alternative for assessing the OGS in digital models for 4 of the 7 variables tested. Other researches are needed to try to adapt the different digital models analysis methods for creating a software designed specifically for this purpose


Subject(s)
Humans , Software Validation , Imaging, Three-Dimensional/methods , Models, Dental/trends , Orthodontics, Corrective , Computer Simulation , Computer-Aided Design , Dental Occlusion
19.
Rev. Salusvita (Online) ; 35(3): 423-435, 2016. tab
Article in Portuguese | LILACS | ID: biblio-833016

ABSTRACT

Introdução: a Prótese Parcial Removível (PPR) é por vezes negligenciada por profissionais quanto a sua confecção clínica e laboratorial e transferência de responsabilidades do cirurgião-dentista ao técnico de prótese dentária. Objetivo: este estudo teve como objetivo avaliar a qualidade de planejamentos e preparos em modelos de trabalho enviados, por acadêmicos e Cirurgiões-Dentistas, à laboratórios de prótese dentária para confecção de PPRs. Método: a pesquisa foi realizada em 8 laboratórios de prótese dentária cadastrados no Conselho Regional de Odontologia do Piauí (CRO-PI), onde foram aplicados formulários com 10 questões fechadas. A amostra foi composta por 60 modelos para confecção de PPR, 30 encaminhados por dentistas e 30 por estudantes. Resultados: os resultados de mostraram que 21 (35%) dentistas utilizaram o gesso pedra para vazar os moldes e 21 (35%) estudantes, o gesso especial; 27 (45%) acadêmicos realizaram os preparos nos modelos, e 24 (40%) dentistas não prepararam os modelos; 2 (3,3%) técnicos receberam desenhos de dentistas e 26 (43,3%) estudantes enviaram os desenhos; 20 (33,3%) modelos de estudantes chegaram delineados e 29 (48,3%) modelos de dentistas foram delineados pelos técnicos; 26 (43,3%) técnicos não tiveram dúvidas nos planejamentos enviados por estudantes e 15 (25%) técnicos tiveram dúvidas nos trabalhos encaminhados por dentistas e 100% comunicou-se para esclarecimentos. Conclusão: concluiu-se que uma parcela considerável de Cirurgiões-Dentistas negligenciam as etapas de preparos de boca e planejamento das PPRs, delegando ao técnico em prótese dentária a maior responsabilidade no planejamento e execução das próteses.


Introduction: the Removable Partial Denture (RPD) is often neglected by professionals regarding their clinical and laboratory preparation and the transference of the responsibility from the dentist to the dental technician. Objective: this study aimed to assess the quality of planning and preparation in removable partial denture casts performed by dental students and dentists sent to the dental laboratories. Methods: the survey was conducted in eight registered dental laboratories in the Regional Council of Dentistry of Piaui (CRO-PI), where the forms was applied, with 10 closed questions. The sample consisted of 60 models for making RPD, 30 referred by dentists and 30 students. Results: the results showed that 21 (35%) dentists used plaster stone for casting and 21 (35%) students were leaked with special plaster; 27 (45%) of the dental students performed preparation in the dental models, and 24 (40%) dentists not prepared models; 2 (3.3%) of the dental technicians received technical designs of dentists and 26 (43.3%) of students; 20 (33.3%) students models arrived designed and 29 (48.3%) of dentists were done by technicians; 26 (43.3%) technicians had no doubt on the planning submitted by students and 15 (25%) had technical issues on the work referred by dentists and 100% communicated for clarification. Conclusion: in conclusion, a considerable number of dentists neglect the steps of mouth preparations and planning of RPDs, delegating to the dental technician the major responsibility in designing and executing removable partial denture.


Subject(s)
Humans , Male , Female , Dental Prosthesis Design/methods , Models, Dental/standards , Denture, Partial, Removable , Students, Dental , Surveys and Questionnaires , Practice Patterns, Dentists' , Dental Technicians , Dentists
20.
Ortho Sci., Orthod. sci. pract ; 9(36): 49-54, 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-852875

ABSTRACT

O sistema Kairalla é um sistema de montagem do aparelho lingual que preconiza a montagem em modelo de set up convencional e é específico para ser utilizado com um bráquete lingual autoligado tridimensional com slot de inserção vertical, neste caso o bráquete 3D® Forestadent. No intuito de facilitar o trabalho do operador e baseado no Sistema Kairalla, este estudo descreve a montagem de um aparelho lingual em que foi utilizado o set up virtual e um modelo prototipado. Com pequenas modificações durante os passos da montagem original foi possível conseguir também um ótimo resultado utilizando o computador como uma outra opção de montagem, que passou a ser mais uma ferramenta muito usada atualmente.


The Kairalla system is a lingual appliance mounting system, and recommends the assembly on the conventional model set-up and is specific for a self-ligating three-dimensional brackets with vertical slots, in this case the bracket 3D® Forestadent. In order to simplify the work of the operator and based on the Kairalla system, this study describes the assembly of a lingual applieance that used the virtual set up and prototyped model. With minor modifications during the steps of the original assembly it was also possible to achieve a great result using the computer as another mounting option, that became another widely used tool.


Subject(s)
Models, Dental , Esthetics, Dental , Orthodontics
SELECTION OF CITATIONS
SEARCH DETAIL